Installation guide
57
NV1
Installation Guide
57
Systems
The unit can be congured with up to 20 systems. A system is a collection of DVRs and cameras
selected from those DVRs. Systems are not formally connected networks but a collection of DVRs
viewable over an IP network. Each system provides access and control of up to 99 cameras at any
one time.
Each individual system can be selected from a drop down menu.
Camera numbering is sequential within that system (up to the maximum 99 cameras per system).
Note: Forlocalcamerafeedstofunctioncorrectly,ensuretherstserveroptionfor
System1isconguredtodisplaythelocalcamerasasshownbelow:
Server URL Server Name Camera Selection
localhost local 1-4, 1-8 or 1-16
System Select from 20 available systems using the drop down menu.
System Name If required, enter a recognisable name for the system (this name
is held on the HD NetVu Console and represents the system).
Server URL Enter the IP addresses of the servers providing the video signals.
Server Name Enter a name for the accompanying requested server (this name
is held on the unit and represents this server).
Camera Selection Select the cameras to be accessed. To select individual cameras,
use the format 1,3,5 or 1:3:5 etc. To select a range of cameras,
use the format 1-3 or 1_3 etc. All connected, non-covert cameras
within the range will be added in numerical connection order.