Installation guide

156
HD NetVu Console
156
Appendix A - Pin-outs - For reference only
Note: Greyed text refers to features that will be available if the mode is changed from Console to
DVR or Encoder, they are not available in the Console conguration. They are included for
reference only.
Alarm & Serial Pin Outs
Using Serial Ports
It is possible to connect a variety of telemetry cameras to the unit, use the following table as a guide
to the serial port connections.
Note: The Serial 1 port and the keyboard connector utilise the same 485 bus which can provide
either keyboard support or telemetry. Both Encoder and DVR mode defaults to telemetry,
Console defaults to keyboard operation.
1
5
6 9
Alarms
The unit supports 4 normally open/closed alarm inputs via the back panel or one Global keyswitch
input with camera specic inputs congurable as entry/exit alarms.
Alarm Connections
Pins Connections
1 - 4 Alarm Inputs 1-4
5 Auxiliary Alarm Input
6-9 Ground
Relays
The unit support up to two 24V 200mA relays
Relay Connections
Pins Connections
6 & 7 Relay 1 signal