Setup guide

Dedicated Micros ©2006
7
Eco
How to Configure Video Inputs and Standard Record Settings
Each of the video inputs on the unit can be individually configured.
This section will describe the full configuration process including resolution and file size, camera
titles, setting a camera to mono, camera fail notification and standard recording settings.
1. Select Cameras -> Camera Set-up
2. It is possible to identify the global camera resolution (common to all video input) the current
option sets the resolution to 704 x 256.
3. Select the required image resolution, enter a file size of between 2K & 45K.
Note: See the Setup Guide for the recommended settings.
4. All connected cameras will be automatically enabled, use this screen to check the enabled
inputs are correct.
5 In the corresponding title box enter the camera name for the video source connected to that
input.
6. Use the drop down box to select whether alarm input polarity is Normally Open, Normally
Closed or Off for each camera alarm.
7. By default the unit presumes all enabled inputs are colour video sources. If you are
connecting a monochrome signal to the unit, it is recommended that the input be set for
mono. Place a tick in the corresponding video input.
8. To enable the unit to send notification that the video input does not detect a 1V peak to
peak signal place a tick in the box below Cam-Fail Reporting. This can send a camera fail
email.
9. Save the configuration by clicking the Save icon.