Operating instructions

Dedicated Micros ©2011MI-I-ECO4/E1-2
90
Eco4
Network
This menu allows additional network settings to be congured if required.
Server Name This eld can be edited to allocate a name to the unit. This would
be used if accessing the unit via a Domain Name Server (DNS).
IP Address This is the IP address allocated to the unit.
Sub Net This is the subnet of the network were the unit is located.
Gateway This is the IP address of the default gateway (router).
Primary DNS This is the primary DNS server IP address for applications utilising
domain names.
Max Transmission Rate Shows the maximum transmission speed for the network type.
Tx Image Buffers This is used in order to improve the picture delivery over Ethernet
when using a slow connection i.e. 256Kbps. A buffer setting of 1,2
or 3 is available.
Ethernet MTU bytes This is the maximum transmit unit for the Ethernet packet. The
MTU is the largest physical packet size measured in bytes that the
network can transmit. By default this gure is set to 1500bytes.
Mx Transmission Timeout ms This is the time (in milliseconds) the unit will wait to re-send a
packet if an acknowledgement is not received.
PPP Base IP Base address for the PPP port
PPP Idle Line Timeout s This is the time (in seconds) the unit will wait before disconnecting
the PPP (Point to Point Protocol) link if data has not been
transmitted or received.