Operating instructions

Dedicated Micros ©2011MI-I-ECO4/E1-2
72
Eco4
Schedule
This menu allows the Schedule function to be congured. This enables the unit to automatically
be put into set/unset mode at specic times on specic days, or at any time under the control of a
keyswitch. This can help reduce unnecessary alarm triggers by preventing alarm detection during
ofce working hours.
When the unit is in Set or Unset mode, combine with different recording qualities and rates under
normal and alarm conditions for a high degree of control in a range of situations.
Note: If Keyswitch is Enabled, the Day Time and Night Time options will not be displayed. The
additional Keyswitch options will instead be displayed.
Mode/Title Enables a name to be congured for Unset, Set and Override
modes.
Current Mode Shows the current timer mode according to the names entered in
the Mode/Title text boxes.
Day Time Enter the time (using the 24hr clock) when Unset mode will begin.
Night TIme Enter the time (using the 24hr clock) when Set mode will begin.
With Keyswitch Enabled
Keyswitch A Keyswitch can be used to switch the recording prole (Unset/
Set).
Note: When the Keyswitch option is set to ‘Enabled’. It is necessary to save (or exit and return to)
the menu. The additional Keyswitch options will then be displayed.
Enable-N/O Select if the Keyswitch is to be normally open (UNSET). Then
choose a contact to be used in a specic zone as the Keyswitch.