Operating instructions
Dedicated Micros ©2009
18
DV-IP RT
RS232
RS485
Note: Refer to Appendix A for further guidance on Serial Port pin allocation for
Telemetry cameras.
Step 9 Connecting a Keyboard
The DV-IP RT supports Dedicated Micro keyboards DM/KBC1 and DM/KBC2. Connect either of
these keyboards via the KBD connector situated on the rear of the unit.
Note: Refer to ‘Unit Operation’ for further guidance regarding supported keyboards.
Step 10 Connecting Telemetry Cameras
Simple Dome Connection
All Domes used inconjunction with the unit should be set with RS485 unterminated at the Dome.
Pin connections for RS485 connection to a dome on serial port 3/4 are:
Dome Cable DV-IP RT Serial Connector
Yellow 1 TX+
Green 9 TX-
If the dome is being connected using an RS485 connection, the dome address should be set to
match the camera input number on the DV-IP RT i.e. if the dome is connected to video input 3, the
camera address should be ‘03’.
DM 2040 & 2060 Domes
A DM 2040/2060 Dome can be connected via either co-axial telemetry or RS485 twisted pair.
If using co-axial telemetry the address switches should be set as:
Blue switch - F Yellow switch - D