Operating instructions
Dedicated Micros ©2009
11
DV-IP RT
Video
8. 16 & 32 way units
VID1 to VID8/VID16/VID32 75Ω BNC composite video input, 1V pk-pk with loop through
available on 8 and 16 input variants.
MON A 75Ω BNC composite monitor output, 1V pk-pk
MON B Spot Monitor output
MON A S Video Connection
HDMI High-Denition Multimedia Interface connectior
Audio
Audio IN (Dual) RCA (phono) socket, 8KHz/16KHz/22KHz sampling 75Ω input
impedance, 1V pk-pk
Audio OUT (Dual) RCA (phono) socket, line level <100Ω output impedance,
1V pk-pk amplication required
8 & 16 way units
8/16 RCA (phono) sockets for each camera channel
Data
SERIAL 1 RS-232 (3 wire & 9 wire)
SERIAL 2 RS-232 (3 wire & 9 wire)
SERIAL 3 (PTZ) RS-485 (2 wire) or RS232 (5 wire)
SERIAL 4 (PTZ) RS-485 (2 wire) or RS232 (5 wire)
USB 2x USB2.0 connectors
IR Infra-Red Input connector for IR Remote Control Extender
NET1 RJ45 Ethernet network connector, 10/100 Mb/s Ethernet Network
NET2 RJ45 Ethernet network connector, 1 Gb/s Ethernet Network
KBD RJ12 connector for use with Dedicated Micros telemetry
keyboards (KBC1, KBC2)
EXP RJ12 expansion port for future use
SATA 2x E-Sata ports available for storage expansion
Power
POWER IEC mains power socket & switch
Alarms and relays
ALARMS IN Via 25-way (female) D Type 24V 200mA
20 general alarm inputs
Range of Alarm states are:
i. 0 – 800R = Short circuit
ii. 800R – 2K = closed contact
iii. 2k – 12k = open contact
iv. > 12K = open circuit
RELAYS Via 9-way (female) D Type rated at 24V 200mA
4 onboard light duty relay output (500mA@ 12V-48V Max)