User manual

DV-IP User Manual v1.01 Feb 28
th
2003
DV-IP User Manual
31
Serial Ports and Telemetry
This page is used to configure the four communication ports on the DV-IP web server.
NOTE: Changes will only take effect when saved and the DV-IP unit is reset.
COM1 & COM2
Debug - Mode that provides useful DV-IP system data.
General Purpose - Engineering test mode.
PPP - Allows remote access via an external modem or terminal adapter
PPP_Link1 (COM2) is the priority PPP port.
PPP_LINK2 (COM1) is a secondary PPP port.
MODEM/TA - Provides dropdown list of modems (PSTN) and terminal adapters (ISDN).
Text in Image - Embeds text into the header of a specific camera with a definable line
length (in characters) and number of lines to record. This file is configured in the
\
ETC
\
paths.ini
file in the DV-IP Web Server Area.
Off - Disables the communication port.
COM3 & COM4
Debug - Mode that provides useful DV-IP system data.
General Purpose - Engineering test mode.
Telemetry - The following telemetry options are available
PPP - Allows remote access via an external modem or terminal adapter.
Text In Image - Embeds text into the header of a specific camera with a definable line
length (in characters) and number of lines to record. This file is configured in the