User manual
DV-IP User Manual v1.01 Feb 28
th
2003
DV-IP User Manual
26
Database Configuration
This page shows you the last time the
Events database was reset, and current
number of events held. It also allows you
to set the maximum number of events
held in the database, and reset the
database, clearing all events.
Alarm Connection Settings
Providing the Report On Alarm option is enabled in the Alarm Zone page, two alternating
profiles provide connectivity to an alarm receiving centre or PC on a Network when used with
the DV-IP Viewer Alarm Receiving software.
Should the first connection fail, the second connection will be tried. Should the second fail,
the first will be tried again, and so on
Hostname - An IP Address, a name defined in the \
etc
\
Hosts
file (the file
Hosts
in the
etc
directory of the DV-IP) or the name of a PC referenced by a DNS server.
Profile - The dial profile is the method by which alarm connectivity is established.
The profile can set as Ethernet to connect over the LAN/WAN/PPP or it can be a named
profile in the DV-IP file C:\
etc
\
profiles
.
DV-IP Alarm Name - This is the name of the DV-IP in alarm conditions, as it identifies itself
to the DV-IP Viewer alarm receiving software.
Note:- The DV-IP Alarm Name has to match the defined folder name in the DV-IP Viewer PC
folder tree.
Dial on Alarm - This needs to be enabled before the DV-IP can connect on alarm. Also
needs to be enabled in the Alarm Set-up page.