Zone Input
This menu allows the conguration of alarm zones. A single or multiple trigger can be used to
generate an alarm. It is possible to allocate up to 32 alarm zones to carry out a combination of
actions. Use these options in conjunction with the Zone Actions menu.
Pre-Alarm sec This is the time period prior to the start of the alarm included
Note: It is recommended that the Pre-Alarm option be set to the same value as the Pre-Trigger
setting in the “Prole Record“ menu. This will ensure successful playback of high quality
Pre-Trigger images. High quality pre-trigger images will only playback properly if review
(playback) starts prior to the pre-trigger initiation.
Alarm Duration sec This is the minimum time period in seconds (from the start of
include the alarm trigger, the pulse extension and any post alarm