Alarms and Presets
Camera 1 - Detected
Pulse extension
> Aux
> 01
> 02
> 03
> - - -
> - - -
005 secs
- -
01
02
04
- -
- -
Module
/Aux
Contact
Input
Source
N/O
N/C
N/C
N/C
N/O
N/O
000
001
002
003
000
000
Preset
Zone
Input
Al
arms an
d
P
resets
000 - 999 secs
Camera XX
The currently selected camera number is displayed, along with its status detected or not detected.
Press a camera button to to congure alarms and presets for that camera.
Pulse Extension
The pulse extension extends the trigger period to avoid double triggers of the same alarms
occurring, i.e. if a second incident of alarm is received after the rst alarm is nished, but still within
this period, the unit will not create a new event.
Module / AUX / Direct
Select whether you are using an external alarm module, the Direct connection or the AUX inputs
on the unit. Up to 16 alarm modules can be connected to the 485-bus network. Select Direct, the
relevant module number or Aux (the default setting is the Aux input).
Contact
This setting identies which contact the Aux or Module selection relates to. Each alarm module has
16 alarm inputs, each input can be used by any camera, or by multiple cameras.
Input Source
Select whether the alarm contact on the alarm device is normally open (N/O) or normally closed
(N/C).
Preset
Camera telemetry presets can be automatically recalled when an alarm is triggered. Enter the preset
number from 000 to 256 for the selected alarm contact