DS2
Write Once Last Reset
This displays the time and date the Write Once process was last reset.
Schedule Rates
This option is enabled by default. With ‘Schedule Rates’ enabled, the unit provides the option
to congure record rates for day, night and weekend operating mode in the ‘Standard Record
Schedule’ and ‘Variable Record Schedule’ menu. Disabling this option will switch the scheduled
recording options to a single set of rates to be used in all schedule (day, night, weekend) operation
modes.
Local 4CIF interlace
This can be switched on if the system will be used to record using the 4CIF settings, and will
eliminate the comb effect that may be visible in a high motion recording environment. It is not
required if not using 4CIF, and may not be required if not recording high motion.
Record Text in Images
The record text in image when enabled has an Edit option to display the submenu for record text
conguration.
Display Text
The text displayed can be automatically removed from the screen after a user dened time or
alternatively the text shall remain on the screen indenitely (default). Select the number of seconds
up to 999 sec maximum.
Keyword Events
When this option is selected to All cameras the unit will add a keyword event trigger to the event
database for every matching word. This can then be accessed via Event Log (press the Event key
on the unit). A Keyword (K) event entry will be displayed as well as the corresponding Zone events,
the K entry will detail the keyword that caused the event.
If this option is set to None then the keyword will still be available as triggers for Zone events.
Record Audio
Selecting Edit next to the Record Options menu entry will open the Audio Conguration menu. Three
channels of audio are recorded on the Digital Sprite 2; there is a choice of two local audio channels
and a single remote channel. This menu will enable or disable audio recording.
The options are:
Audio Sampling - Audio can be recorded at 8Hz, 16Hz or 22Hz.
Audio in 1 & Audio in 2 - Enable when recording through the audio input. Audio 1 is
associated with Camera 1, Audio 2 is associated with Camera 2.
Remote Audio - Enable this to record network audio from NetVu ObserVer
Audio Output 1 - Enable this to be able to send audio signals out of the unit via Output 1
(typically used to send audio to a remote speaker).
Audio Output 2 - Enable this to output the audio from the camera being viewed, either
Camera 1 or Camera 2, mixed with network audio to a local control room speaker.
Audio in Level/AGC- This option allows the Audio in level to be set, between 0 and 15. This
is the base setting from which the Automatic Gain Control (AGC) will operate.
Audio out 1 Volume - This unied setting controls the level at which audio is sent via both
Audio Output connections.