DS2 Setup Guide

Dedicated Micros ©2007
56
DS2
Zone on Exit Route
This feature is similar to the zone on entry option, but works in the reverse, this allocates an exit
route from the keyswitch to the exit allowing an operator to enable the alarm system for the premises
and allow them to pass through the specied alarm areas without triggering the alarm, in compliance
with BS8418, the British Standard for remote monitoring stations. Diversion from the exit route will
result in an alarm being triggered immediately. This feature is only available when Advanced Alarms
are enabled.
Entry Initiator
This is part of the Advanced Alarm Features and when activated will trigger the entry timer. This is
the count down timer that will automatically start when the entry initiator is triggered (e.g. front door)
and works in conjunction with the entry route to ensure the alarm system is not activated by other
alarm triggers on the entry route for this set time.
Exit Terminator
Once the keyswitch is switched on the alarm system will wait for the exit timer to expire to ensure
everyone has exited the building via the exit routes. This timer can be terminated earlier by
triggering an exit terminator, e.g. closing the front door
Change Record Rate
Create Database Entry
Connect on Alarm
Archive Alarms
Protect Alarm Images
Both
Enabled
Enabled
Enabled
Enabled
Both, Standard, Variable, None
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Zone
0
1 Actions
Change Record Rate
This allows the record rate to be switched to the alarm rate when the zone is active.
The options available are:
Standard - switches cameras enabled for standard recording to the alarm record rate.
Variable - switches cameras enabled for variable recording to the alarm record rate.
Both - applies to both the variable and standard recording of the selected camera.
Note:
When Both is selected the record rates set in the standard and variable record menus will
be added, i.e. if standard is set to 6PPS for 6 cameras (1PPS per camera) and the variable
is set to 3PPS, then that camera will record at 4PPS.
Create Database Entry
An alarm entry will be added to the event database. The zone title will be used as part of the entry
information.
Connect on Alarm
The unit will automatically connect to the remote alarm monitoring station. This features is useful in
applications where remote monitoring of multiple sites is required.
Note:
The remote reporting settings must be congured and the viewing application must be
enabled to receive remote alarm video, for more details refer to the Networking Guide.
Archive Alarms
This will force the unit to automatically download the alarm images via FTP to a central FTP Server
or directly to a local CD.
Tip: