DS2 Setup Guide

Dedicated Micros ©2007
53
DS2
Activation Type
Active
Schedule Activation
Day Night Weekend
24 Hour Activation
Zone Activatio
n
Schedule Activation
This allows the Operator to congure when an alarm will be active, i.e. active during Day and
Weekend but inactive at Night.
Move the cursor to the required setting and press the or to include or exclude from the Day,
Night or Weekend options.
24Hr Activation
This would be the setting for alarms that do not want to change at any time and will remain as
programmed, for example the Panic Alarm.
Note:
Setting this option overrides the Event Active setting determined in the Standard Recording
Schedule.
Zone Settings
Each zone is allocated standard settings which can be modied to suit the requirement of the
system.
Note:
Select the Zone to be congured before entering the Zone Settings menu.
Title
Pre-Alarm time
Alarm Duration
Zone Alarm Input
Zone OR Input
Zone AND Input
Zone NOT Input
Zone 01
002 secs
010 secs
No contact
No contact
No contact
No contact
000 - 999 sec
000 - 999 sec
Zone
0
1
S
ettin
g
s
Title
A 24 character title can be allocated to each zone, this information is stored within the event
database therefore a name with signicance is recommended.
Pre-Alarm Time
This is the period of time, prior to the alarm start that will be included along with the alarm recording
for archive. These images will be protected from being overwritten with the alarm images.
The unit places a ‘marker in the regular recording that acts as the start of the pre-alarm recording,
the number of images available will be dependant on the pre-alarm time set.
Note:
If recording is not enabled there may not be any images on the disk. If pre-alarm recording
is required, ensure recording is enabled.