Setup guide
33
ENGLISH
General Contact
The Digital Sprite 2 has 32 General Contacts that can be accessed and
configured within this menu, Use the button to select the required contact.
Enabled
Each input can be enabled or disabled. Highlight the option and use the or
buttons to enable or disable the input.
Module
The on-board (AUX) alarms and the on-board Direct Alarm modules can be
selected for configuration, as well as module 1 through to module 16.
Contact
Where multiple alarms are available, the relevant contact can be selected.
Input Source
The alarm inputs can be configured as Normally Open (N/O) or Normally
Closed (N/C).
Pulse extension
A pulse extension (000 - 999 seconds) can be added to each alarm input.
A pulse extension extends the trigger period to avoid double alarm triggers
from occurring, i.e. If a second trigger occurs on the same alarm input within
the pulse extension time period, the unit will not create a new event.
General Contacts
1-32
Aux, Direct, 01 - 16
01-20
N/O, N/C
000 - 999
General Contacts 1 2 >>
Enabled
Module Aux Aux
Contact 01 01
Input Source N/O N/O
Pulse extension (sec) 000 000
VMD Options
The Digital Sprite 2 supports Video Motion Detection and Activity Detection
functionality, this menu allows the global parameters of this feature to be
configured.
VMD Protect Period
Any VMD event can be protected from being overwritten. The protection period
can be set as a number of days or indefinitely, ensuring the files are always
available. The files will be automatically overwritten after the configured period
has expired.
Note: Protecting images will reduce the hard disk capacity. This should be
taken into account when specifying hard disk requirements.
VMD Pulse Extension, Pre-Alarm Time and Alarm
Duration
The pulse extension extends the trigger period to avoid double triggers of VMD
occurring, i.e. If a second incident of VMD is received, after the first alarm is
finished but within this period, the unit will not create a new event.
Pre-Alarm Time
This is the period of time, prior to the VMD trigger, that will be included along
with the VMD recording for archive and protected.
VMD Options
VMD protect period Set period
000 days
VMD pulse extension 002 secs
VMD alarm duration
Cell display
002 secs
Disabled
VMD pre-alarm time 000 secs
Relays
VMD buzzer
Edit
No
000 - 999, Indefinitely
000 - 999 secs
000 - 999 secs
000 - 999 secs
Disabled, Enabled
No, Yes