Setup guide
31
ENGLISH
Note: When Both is selected the record rates set in the standard and variable
record menus will be added, i.e. if standard is set to 6PPS for 6 cameras
(1PPS per camera) and the variable is set to 3PPS, then that camera will
record at 4PPS.
Create Database Entry
An alarm entry will be added to the event database. The zone title will be used
as part of the entry information.
Connect on Alarm
The Digital Sprite 2 will automatically connect to the remote alarm monitoring
station. This features is useful in applications where remote monitoring of
multiple sites is required.
Note: The remote reporting settings must be configured and the viewing
application must be enabled to receive remote alarm video, for more details
refer to the Networking Guide.
Archive Alarms
This will force the Digital Sprite 2 to automatically download the alarm images
via FTP to a central FTP Server or directly to a local CD.
Refer to Archive on Event in the Record Option menu.
Protect Alarm Images
If the recorded alarm images are to be automatically protected (indefinitely or
for a set period) then the ‘Protect Alarm Images’ option must
be enabled.
The example translates into; an alarm must be received on input 1 AND input
3 but NOT on input 4 OR an alarm must be received on input 2 AND input 3
but NOT on input 4.
Be aware if an alarm is received on input 4 under the above circumstances the
event will not be triggered.
Zone Actions
This identifies the actions that will be allocated to the zone being configured.
Note: The actions are divided over three pages.
Page
This will scroll through all the available actions, there are three pages of
actions. Use the buttons to scroll through the pages.
Change Record Rate
This allows the record rate to be switched to the alarm rate when the zone is
active.
The options available are:
• Standard - switches cameras enabled for standard recording to the alarm
record rate.
• Variable - switches cameras enabled for variable recording to the alarm
record rate.
• Both - applies to both the variable and standard recording of the selected
camera.
Zone 01 Actions
Page Page 1
Enabled
Standard, Variable, None
Disabled
Disabled
Disabled
Text Only Alarm Disabled
Change Record Rate
Both
Archive Alarms Enabled
Create Database Entry
Enabled
Connect on Alarm Enabled
Zone 01 Actions
Page Page 2
Disabled
Module 1 Relay 1, Aux Relay 1
Low Res, Medium Res, Hi res
Disabled
Enabled
Protect Alarm Images Enabled
Close Relay
No Relay
Record Still Images
Disabled
Email Image Enabled
Email Image Res. Thumbnail