Setup guide
29
ENGLISH
Alarm Zone Config
An alarm zone logically groups alarms and initiates actions when an alarm is
activated. Each Alarm Zone can be individually configured within this menu.
Zone
There are 32 zones that can be individually configured and allocated actions.
Use the or buttons to scroll through the zones.
Pre-Configured Zones
There are a number of pre-configured zones that have the following functions,
however these can be reconfigured if required.
• Zone 1 to 16 - Camera Alarms.
• Zone 30 - Disk Low.
• Zone 31 - Disk Full.
• Zone 32 - Panic Alarm.
Zone Activation
Each zone can be scheduled to be always enabled (24Hr) or individually
activated during the day, night and at weekends.
Schedule Activation
This allows the Operator to configure when an alarm will be active, i.e. active
during Day and Weekend but inactive at Night.
Move the cursor to the required setting and press the or to include or
exclude from the Day, Night or Weekend options.
24Hr Activation
This would be the setting for alarms that do not want to change at any time
and will remain as programmed, for example the Panic Alarm.
Note: Setting this option overrides the Event Active setting determined in the
Standard Recording Schedule.
Zone Settings
Each zone is allocated standard settings which can be modified to suit the
requirement of the system.
Note: Select the Zone to be configured before entering the Zone Settings
menu.
Title
A 24 character title can be allocated to each zone, this information is stored
within the event database therefore a name with significance is recommended.
Pre-Alarm Time
This is the period of time, prior to the alarm start that will be included along
with the alarm recording for archive. These images will be protected from
being overwritten with the alarm images.
Alarm Zone Configuration
Zone 01
Zone 01 actions Edit
Zone 01 settings Edit
Primary camera Zone 01 01
01-32
Selected cameras, All cameras
Zone 01 Activation Edit
Select zone 01 cameras Selected cameras
Zone Activation
Zone 01 Schedule Activation
24 Hour Activation
Active NightDay Weekend
Activation Type Schedule Activation
Zone 01 Settings
Title Zone 01
Pre-Alarm Time 002 secs
Zone Alarm Input No contact
Alarm Duration 010 secs
Zone OR Input No contact
Zone AND Input
Zone NOT Input
No contact
No contact
000 - 999 seconds
000 - 999 seconds