Setup guide
28
ENGLISH
Global alarm
It is possible to allocate Aux Relay 1 to trigger on receipt of any alarm.
Global VMD
It is possible to allocate Aux Relay 2 to trigger on receipt of notification on the
system of video motion detection on any camera.
Global camera fail
It is possible to allocate Aux Relay 3 to trigger on receipt of any of the video
inputs having camera failure (video loss), this is when the video signal drops
below the 1 Volt pk-pk threshold.
Relay test
The relay test option provides access to a submenu where any of the relays
(on-board and additional relay module) can be tested, i.e. manually triggered.
Highlight the relay test option and select Edit, this will display the submenu.
Move the cursor to the Aux section and press to switch between the Aux
and Module option (the Module option is only displayed if an additional relay
module is connected).
Highlight the relay and select it for test by using the or buttons. To test
the relay, highlight the On / Off option and press or to trigger the relay.
The corresponding box will be blank if the relay is off or filled if the relay is on.
Note: When an alarm module is selected, the number of relays shown on the
menu will increase to 16.
28
Spot alarm display (MON B)
• Last - If a number of alarms are triggered at the same time, the last alarm
image will be displayed on the monitor.
• Sequence - This will display all alarm images in a sequence.
These settings can be applied for alarm triggers, activity detection, both or
alternatively the option can be disabled by selecting Off.
Alarm Buzzer
The unit has a built in alarm buzzer which can be configured to trigger when
an alarm is received on the Digital Sprite 2.
Camera Fail Buzzer
The unit has a built in buzzer which can be enabled to be automatically
triggered if any of the video inputs no longer detects the 1Volt pk-pk signal.
This buzzer can be enabled or disabled within this menu, by default the option
is disabled.
Relays
The relays on the Digital Sprite 2 can be configured to automatically trigger
under certain conditions. This option also allows the relay on the unit to be
tested.
Relay Setup
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Global VMD
Global alarm
(Aux Relay 2)
(Aux Relay 1)
Enabled
Enabled
Global camera fail
Relay test
(Aux Relay 3)Enabled
Edit
Relay Test
Relay test
Relay 1 Off
123456
Aux