Setup guide
25
Alarms and Presets
Alarms and Presets Camera XX Detected Not Detected
Telemetry protocol None B B V, Pelco, DM, (serial telemetry dome)
Preset Module Contact Input
> -- 01 01 N/O
> -- --
Camera XX
The currently selected camera number is displayed, along with its status –
detected or not detected. Press a camera key to select a camera to configure
alarms and presets for that camera.
Telemetry protocol
Select the telemetry protocol for the camera; BBV, Pelco, DM, or the serial
telemetry dome selected in the ‘System Options’ menu page.
BBV and Pelco is Coaxial telemetry, if you are using Pelco serial telemetry it is
displayed as ‘Pelco-P’. DM telemetry is twisted pair DTMF telemetry (using a
TAD3) or 485-Bus telemetry.
Note: Autopan and patrol (tour) modes are not available when using Pelco
coaxial telemetry.
Notes for JVC domes: If you are using JVC domes there are two types of serial
telemetry, type 1 and type 2. Select the correct type to correspond to the model
number from the list below:
Type 1 Type 2
T K - C 6 7 5 E T K - C 6 7 5 B E
T K - C 6 7 5 U T K - C 6 7 5 B U
T K - C 5 5 3 E
Preset
If the camera has telemetry presets configured, these can be recalled when
an alarm is triggered. Enter the preset number from 00 to 99 for the selected
alarm contact.
Module
Select the address of the alarm module being used, up to 16 alarm modules
can be connected to the 485-bus network, the default setting is alarm module 1.
Contact
Each alarm module has 16 alarm inputs, each input can be used by any camera
or multiple cameras.
Input
Select whether the alarm contact on the alarm device is normally open (N/O)
or normally closed (N/C)
7211 DigitalManual Update 10/4/02 5:12 pm Page 25