Setup guide

Dedicated Micros Page 75
It is possible to use a combination of the keyswitch and the schedule option. If an operator
forgets to unset the alarms when the keyswitch is disabled the schedule will override the
keyswitch at the next set time.
Function Description
Schedule Type This identifies the how the schedule will operate, the options
available are:
Timed - allows settings to be configured for set times during the day,
night and weekend operation modes.
Zone Control - This enables or disables Night Zone or Weekend
Zone settings.
Schedule Record
Rates
If this option is disabled then the record settings for day, night and
weekend operation mode will be replaced by a single Rate option in
the Standard record menus.
Operation Mode 1 Title
This title identifies the mode of operation for Mode 1 (DAY default).
Operation Mode 2 Title This title identifies the mode of operation for Mode 2 (NIGHT
default).
Operation Mode 3 Title This title identifies the mode of operation for Mode 3 (WEEKEND
default).
Keyswitch Enable When the keyswitch option is enabled it is necessary to identify the
input that will be used to trigger the keyswitch, the options are
Direct, Aux and Module 1 to 16.
Keyswitch – Normally
closed
The keyswitch by default will be configured as normally open,
however it is possible to change this to normally closed operation.