Setup guide

Page 72 Dedicated Micros
How to Configure the Alarm Database
The Digital Sprite 2 supports numerous logs which will store information on the
actions and processes the Digital Sprite 2 carries out.
As we have identified the alarms and enabled these to function it is necessary
to ensure the database can support and register all the configured alarms.
To configure the database parameters:
1. Select Alarms/VMD -> Database Configuration.
2. The last database reset time will be displayed; this is a read only section.
3. The current number of entries in the database will be displayed; this is a read only section.
4. Enter the maximum number of entries for the database file, once this figure has been
reached the database will ‘wrap round’ and start entering over the top of entry 1.
5. To reset the database select Save Settings, you will then be prompted to reset the
database, select OK to reset or cancel.
Function Description
Protect Images Any images that have not been protected or require the protect period
extending can be selected in the protect image partition summary and
then the time the images are to be protected can be identified in days.
Protect Images
Indefinitely
If images are never to be overwritten the they can be protected
indefinitely.
Function Description
Last database
reset time
This is a read only section and is generated by the Digital Sprite 2, it
identifies the last time that the database was reset.
Current number of
entries
This is a read only section and is generate by the Digital Sprite 2, it
identifies the current number of entries in the database.
Maximum number
of entries
This is the maximum number of events that will be logged in the
database. When this figure is reached the database will start overwriting
the entries starting at entry 1.