Setup guide
Page 60 Dedicated Micros
How to Configure FTP Settings for Archiving Images
The Digital Sprite 2 can archive images to a central FTP server or to the internal
CD writer; this can be on receipt of an alarm or VMD using a scheduled time to
backup the video.
When using FTP in a multi-unit application this ensures that all files are stored
in one central location for each of the Digital Sprite 2s, offering efficient file
management and easier review capabilities.
To configure the FTP information:
1. Select Network -> FTP Events Download.
Function Description
Unit Alarm Name This is the name that will be presented to the remote alarm viewing
application and therefore should have some significance to the Operator.
This name must match the defined folder name in the Viewer PC folder
tree.
Report Alarm
Reporting
This must be enabled for the Digital Sprite 2 is to automatically connect
on alarm, it must also be enabled in the Alarm Zone option.
Report Camfail
Reporting
If the Digital Sprite 2 identifies camera failure on any of the inputs,
enabling this option will force the unit to connect to the remote alarm
station.
Report Startup
Reporting
This will send an alarm report when the Digital Sprite 2 starts up, this will
identify any system resets.
Dial Retry Time If the initial connection attempt fails then the Digital Sprite 2 will wait for
the specified time period before attempting to re-connect.
Dial Limit This identifies the number of times the Digital Sprite 2 will attempt to
connect to the remote alarm monitoring station after a failed attempt. A
setting of 0 identifies no limit and the Digital Sprite 2 will continue to try
and connect until it is successful.
Alarm Telnet
Server Port
This specifies the network port number to use for reporting to the alarm
server. This is normally left at the default value.
Note: It is also possible to archive images directly to the internal CD, refer to the
Setup Guide for full details on how to select download to CD for archiving.