Setup guide

Page 54 Dedicated Micros
How to Configure Connect/ Dial, FTP, SMS and Email on Alarm
As described in the Alarm Zone section above there are a number of actions that can be
initiated when the Digital Sprite 2 is in receipt of an alarm trigger.
For these actions to operate correctly there are additional configuration requirements; FTP
server address, SMS / GSM settings and SMTP Server address. Without this information the
Digital Sprite 2 would not have a route to transmit images on receipt of an alarm or notification of
VMD. This section will be separated into the configuration processes required to enable these
functions to operate.
How to Configure Connect/Dial on Alarm
It is possible to force the Digital Sprite 2 to transmit a message to an allocated
Viewer on receipt of an alarm. This connection can be via the Ethernet port of
the unit or via a dial up connection on the serial port of the unit.
The message will be transmitted to the remote station to notify them of an alarm
on the system. The operator can then make a connection to the unit to verify
and action the alarm response.
Function Description
Global Alarm It is possible to configure Relay 1 default as the global alarm relay, this
means that the relay will close when an alarm is received on any of the
alarm inputs.
Global VMD It is possible to configure Relay 2 default as the global VMD relay, this
means that the relay will close when VMD is identified on any of the
camera inputs.
Global Camera Fail It is possible to configure Relay 3 default as the global camera fail relay,
this means that the relay will close when there is notification on the
system that any of the enabled video inputs has camera failure (no 1V
pk-to-ok signal).