Setup guide
Page 50 Dedicated Micros
Function Description
Change Standard
Record Rate
This will change the record rate of the cameras that have been identified
in the Standard Record Rate page (refer to Camera Set-up for
information on how to configure standard record rate). The cameras will
switch to the alarm record rate specified.
Note: Changing the zone cameras has no effect on which cameras have
their standard record rate changed.
Change Variable
Record Rate
This changes the record rate of the cameras that are selected in the
alarm zone to the variable record rate previously specified (refer to How
to Configure Variable Record Rate in this section of the manual). Each
of the cameras must have an alarm record rate specified.
Connect/Dial on
Alarm
The Digital Sprite 2 will automatically connect to the remote alarm
monitoring station defined.
Note: You need to enable the dial on alarm system feature for this
function to work.
Alarm Enabled in
Day operation
mode
Each alarm can be configured to be active when the unit is in a specific
operation mode, enable this for the alarm to be active in Day operation
mode.
Alarm Enabled in
Night operation
mode
Each alarm can be configured to be active when the unit is in a specific
operation mode, enable this for the alarm to be active in Night operation
mode.
Alarm Enabled in
Weekend operation
mode
Each alarm can be configured to be active when the unit is in a specific
operation mode, enable this for the alarm to be active in Weekend
operation mode.
24 Hour Alarm This option would be enabled for alarms that do not want to change at
any time and will remain as programmed, i.e. Panic Alarm. When this is
selected the day, night and weekend options are not available.
Record still image This will record a still image of the trigger along with the standard
recording. Still images are accessible through the Live page of the web
interface. This will also add the word ‘alarm’ to the title header.
Protect alarm
Images
Alarm images can be automatically protected from being overwritten.
Archive Alarms This will force the Digital Sprite 2 to automatically download alarm
images via FTP to an FTP server or directly to the local CD writer.