To allocate the cameras and actions that will be carried out when an alarm is received:
13. Select the cameras from the select zone camera list which are to be included in the zone
being configured. To select a camera click the mouse over the cameras these will then be
highlighted. At least one camera must be highlighted at all times.
14. All of the alarm zone actions can be allocated to each of the zones, to select all actions,
place a tick in the select all box.
15. To select individual actions place a tick alongside the relevant action, see the table below
for more information on the actions listed.
16. If multiple cameras have been selected a primary camera must be allocated to the zone,
select the corresponding camera from the drop down list. The primary camera is the camera
that a still image will be taken from for e-mailing on alarm and will be the first camera displayed
on the Operator monitor.
17. It is possible to send a camera to a preset position on receipt of an alarm, identify the
preset number and the corresponding camera that is to be switched.
18. It is possible to automatically close a relay output when an alarm zone is triggered, the
relay can be connected to an external device; door entry system, loudspeaker announcement
system which means the system can function automatically without user intervention. Select the
relay that is to be actioned on receipt of an alarm.
19. An e-mail can be sent to an e-mail server on alarm, enable this option and identify the
resolution of the image that will be attached to the e-mail.
20. Save the information configured by selecting Save Settings!