Setup guide
Dedicated Micros Page 47
Function Description
Pre-Alarm Time This is the period of time prior to the alarm start that will be included
along with the alarm recording for archive and these images will also be
protected from being overwritten.
Alarm Duration This is the minimum time period in seconds from the start of the alarm
that will be protected from being overwritten. This time will include the
alarm trigger, the pulse extension and any post alarm recording, it will
not include the pre-alarm images.
Zone Alarm Input This determines which input or system function will trigger the zone
alarm, the options are; Contacts 1 to 32, VMD 1 to 16, Presets 1 to 16,
Disk low, Disk full, Panic and no contact.
Zone OR Input The Zone OR Input identifies an alternative input that can also be used
to trigger the zone alarm. This means an alarm trigger can be received
on the Zone Alarm Input or the Zone OR Input for the trigger to be
activated, the options available are the same as the Zone Alarm Input.
Zone AND Input The Zone AND Input identifies that an alarm trigger needs to be received
on both the Zone Alarm Input and the Zone AND Input for the trigger to
be activated and the alarm action to the automatically initiated. The
options available are the same as the Zone Alarm Input.
Zone NOT Input The Digital Sprite 2 will only issue the alarm actions if the trigger is
received on the zone alarm input and not on the Zone NOT input. The
allocated alarm triggers available are the same as the Zone Alarm Input.
Regular
Recording
Alarm Starts
Alarm Ends
Event Pre-Alarm
(Protected)
Pulse Extension
Event Duration
Alarm Duration (Min Protection)
Rate
PPS
Time
Event
Recording
Regular
Recording
Enhanced
Pre Alarm