Setup guide

Dedicated Micros Page 43
Walk Test
This is part of the configuration process and will provide you with a
low resolution image to check that the settings made for VMD
activity cover the required area(s).
A thumbnail will be displayed and any triggers will be displayed on
this screen this will enable you to add zones if all areas are not
covered increase or decrease the sensitivity, etc.
Using the Walk test will ensure that you are satisfied with the
configuration and remove the need to revisit the site.
How to Enable and Configure Alarms
The Digital Sprite 2 supports 17 alarm inputs which can be individually
configured.
This section will be divided into:
Enabling and configuring the alarm inputs
Enabling and configuring the alarm actions
By default the 16 alarm inputs are disabled, these need to be enabled so that external alarm
devices can be connected to the Digital Sprite 2.
1. Select Alarms/VMD -> Alarm Inputs
2. Place a tick in the box under the Enabled option to select all the alarm inputs or individually
tick the required alarm(s).
3. Select the input that the alarm will be triggered on from the drop down menu, select the
contact number.
4. Select whether the input is Normally Open or Normally Closed by default.
Note: A VMD Zone can be used to trigger an Alarm Zone, refer to How to Enable and
Configure Alarms for more information.
Note: There are 16 alarm inputs on board the unit and the option for an additional 16
alarm inputs (17 to 32) by connecting a DM alarm module to the Digital Sprite 2.
Ensure the additional alarm module is connected to the Digital Sprite 2 before
powering up the unit.