Setup guide

Dedicated Micros Page 131
Camfail
This report will be generated if the Digital Sprite 2 identifies that any of the video inputs does not
have a 1V peak-to-peak signal.
CAMFAIL?<name>&<time>&<lat>&<long>&<speed>&<course>&<zone>&<upper>&
<lower>
camera This is the video input number that is directly associated with the
alarm on the Digital Sprite 2.
vmd zone VMD zones are configured on the Digital Sprite 2, this identifies the
zone that has been activated to initiate the SMS message.
name This is the system name configured on the Digital Sprite 2.
time This is the local julian time of the message. The julian time is the
number of seconds since 00:00:01 hour on January 1st 1970. If the
Verbose message option has been enabled on the Digital Sprite 2 this
message will be in a human readable format.
lat This parameter is not relevant to the Digital Sprite 2 and included to
support other Dedicated Micros platforms.
long This parameter is not relevant to the Digital Sprite 2 and included to
support other Dedicated Micros platforms.
speed This parameter is not relevant to the Digital Sprite 2 and included to
support other Dedicated Micros platforms.
course This parameter is not relevant to the Digital Sprite 2 and included to
support other Dedicated Micros platforms.
zone This parameter is not relevant to the Digital Sprite 2 and included to
support other Dedicated Micros platforms.
upper This identifies the bitmask of failed cameras 33 – 64.
lower This identifies the bitmask of failed cameras 1 - 32.