Operating Instructions and Installation Instructions
Dedicated Micros ©2010
67
CamVu 2000
DRAFT
Global Actions
This menu details how to congure the default relay actions supported on the unit.
The unit supports two onboard relay connect
ions and global relay settings. These global relays can be trigge
red
under specic conditions i.e. on receipt of any alarm or any notication of Activity
Detection
.
Image Protection Period Select a time period (in days) that images associated with an alarm
will be protected from deletion.
Alarm Display Alert Enable this setting to display an alarm text alert in the colour specied
in ‘Alarm Colour’ in the Zone Actions Menu.
Normally Alllows the normal state of the Contact to be congured.
On This option will enable detection of the condition listed on the left ie.
if the checkbox next to ‘VMD/Activity’ is selected, the VMD/Activity
condition will be monitored; options are Zone, VMD/Activity, Camera
Fail, System Set, Dial Out, System Override, Camera Masked, Is
Recording and Not Recording.
Status (Green) Opens the System Settings->Status->Unit Status page.
Alarm In (Yellow) Opens the Alarm Settings->Alarm Input->Alarm Input Conguration
page.
Zone Act (Blue) Opens the Alarm Settings->Zone Actions->Zone Action Conguration
page.
Refresh (Purple) Refreshes the current page.