Note: It is recommended that the Pre-Alarm option be set to the same value as the Pre-Trigger setting
in the “Prole Record“ menu. This will ensure successful playback of high quality Pre-Trigger
images. High quality pre-trigger images will only playback properly if review (playback) starts
prior to the pre-trigger initiation.
Alarm Protect sec This is the minimum time period in seconds (from the start of the
alarm) that is protected from being overwritten. This time will include
the alarm trigger, the pulse extension and any post alarm recording. It
will not include pre-alarm images.
Zone Input Rules
Input This sets an input or system function as the primary alarm trigger.
Select from Alarms 1-32, Activity 1-16, Preset 1-16, Disk Low,
Disk Full, Panic, Archiving Slow, Archiving Fault, Virtual 1-16, and
Keyword Channel 1-32 (which will trigger the Alarm if any or the 32
programmed keywords are detected on the selected channel).
Alarm 24Hr This option can be enabled for alarms that do not require change at
any time and are to remain as programmed i.e. Panic Alarm. When
this is selected, the Set, Unset and Override options are disabled.
Entry Route Zone This creates deferred alarms along a specied route while the
entry time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the entry
route during the countdown will result in the alarm being triggered
immediately. This allows staff entry without triggering an alarm prior to
switching the system to Set mode.
Exit Route Zone This creates deferred alarms along a specied route while the
exit time is active. This is in compliance with BS8418 (the British
Standard for remote video reporting centres). Diverting from the exit
route during the countdown will result in the alarm being triggered
immediately. This allows staff to exit without triggering an alarm.
Exit Terminator This will trigger the exit timer if the system is set. A countdown timer
will automatically start when the alarm is activated and ensure the
alarm system is not activated by other specied alarm triggers for the
Set time i.e. allowing a Guard to exit a building.
Entry Initiator This will trigger the entry timer if the system is set. A countdown timer
will automatically start when the ‘primary’ alarm trigger i.e. front door,
is actioned. This ensures the alarm system is not activated by other
specied alarm triggers for the set time
Note: Unset, Set and Override modes may be renamed via Record Settings->Schedule.
Enable in Unset Each alarm can be congured to be active when the unit is in a
specic operation mode. Enable this for the zone alarm to be active in
Unset operation mode.
Enable in Set Each alarm can be congured to be active when the unit is in a
specic operation mode. Enable this for the zone alarm to be active in
Set operation mode.
Enable in Override Each alarm can be congured to be active when the unit is in a
specic operation mode. Enable this for the zone alarm to be active in
Override operation mode.
Activity (Green) Opens the Alarm Settings->Activity Setup page.
Zone Act (Zone Act) Opens the Alarm Settings -> Zone Actions page.
Alarm In (Alarm In) Opens the Alarm Settings -> Alarm Input Conguration page
Refresh (Purple) Refreshes the current page.