Operating Instructions and Installation Instructions

Dedicated Micros ©2010
115
CamVu Mini Dome
IP Stream Inputs
The IP Streams menu allows the selection of High, Medium and Low resolution settings for video sources
originating from a network based source i.e. IP Server. These streams are congured on the remote device.
This feature is predominately intended for use with 3rd party IP camera streams (connected via the 3rd party
IP camera unlock feature).
Note: The IP Stream needs to be set to Simple Streaming on Camera->Setup.
Note: There is only normal ‘non event’ recording for connected IP cameras.
Channel Select a camera channel for review and adjustment. Only those
cameras designated as ‘IP’ in the Camera Setup menu will be
available (Conguration menu:Camera Settings->Camera Setup).
Copy to all Select this option to apply current settings to all
connected cameras.
The following options can be congured for Set, Unset and Override record proles when operating under
Normal (non Event) conditions. Refer to Conguration Menu:Record Settings->Prole Record for information
regarding record modes.
Comp Select image compression format (MPEG or JPEG).