User guide

Dedicated Micros ©2011
82
CamVu D500 Minidome
Public (NAT) Address This is the public IP (or domain name) for a unit connected to the
Internet via a NAT Router or Firewall. This eld should be left blank if
NAT is not used e.g. a private network.
Video Server Port This eld allows the RVRC to connect to the unit through a router that
is using port forwarding e.g. if the camera does not appear on port
80 (HTTP), to the external network. Enter the port number used for
forwarding here if required.
Alarm Server ref. ID This is the reference name/ID that will be presented to the RVRC
viewing application. It should therefore have some signicance to the
Operator.
Remote Alarm Reporting This must be enabled for the unit to automatically connect
on alarm.
Remote Cam Fail Reporting Enabling this option ensures the unit reports camera failure on any of
the inputs to the RVRC.
Remote Startup Reporting This will send an alarm report when the unit starts up. Any system
resets will be identied.
ARC Ping Enabled
Should the modem/router at the Alarm Receiving Centre be dormant, the
unit will ‘Ping’ the ARC prior to sending reporting data.
Alarm Responder Port This species the network port number used for reporting to the alarm
server. In normal circumstances this should be left at the default value
(23).
Dial Retry Time (secs) If the initial connection attempt fails, the unit will wait for the specied
time period (in seconds) before attempting to re-connect.
Dial Count This identies the number of times the unit will attempt to connect
after a failed attempt. A setting of ‘0’ means no limit and the unit will
continue to try and connect until successful.
Zone Act (Green) Select to open the Alarm->Zone Actions menu
Network (Yellow) Select to open the Network->Network menu
E-mail (Blue) Select to open the Network->E-mail menu
Refresh (Purple) Refreshes the information on the current page