User guide

Dedicated Micros ©2011
74
CamVu D500 Minidome
Tip: Use DHCP to locate a free IP address, then x the unit IP address to the free one by entering
the details into the IP address, subnet and gateway elds.
Max Transmission Rate kbits/sec This shows the maximum transmission speed for the network type
being used. If set to ‘0’, transmission speed is not limited in the
camera.
Note: This setting will limit and override any higher transmission rate entered in the Video
Transmission menu (Conguration menu->Live Trans).
Force 10BaseT operation The unit supports 10 or 100BaseT half duplex transmission. Selecting
this option will force the unit to operate at a 10BaseT connection.
Tx Image Buffers This is used in order to improve the picture delivery over Ethernet
when using a slow connection i.e. 256Kbps. A buffer setting of 1,2 or
3 is available (default setting is 1).
Ethernet MTU Bytes This is the maximum transmit unit for the Ethernet packet. The MTU
is the largest physical packet size measured in bytes that the network
can transmit. By default this gure is set to 1500bytes.
Max Transmission Timeout ms This is the time (in milliseconds) the unit will wait to re-send a packet
if an acknowledgement is not received.
Reset (Red) Resets the unit to apply changes.
Rem Report (Green) Opens the Network Settings->Remote Reporting page.
Webcam (Yellow) Opens the Network Settings->Web Camera Conguration page.
Email (Blue) Opens the Network Settings->Email page.
Refresh (Purple) Refreshes the current page.