User guide

Dedicated Micros ©2011
28
CamVu D500 Minidome
System Features Network
Secondary Web Port If the default port setting for web serving has already been allocated,
it is possible to congure a second port number i.e. the secondary
web port can be set to 8000 if the default web port (80) is blocked by
the network or rewall.
Use Record Proles for Tx High Select this option when units required Video Transmission prole
(rate/quality/resolution) is identical to that being recorded.
Auto IP Override. This is set to disabled when the camera is congured. Enable to
attempt Zero Cong address negotiation.
Max Client Connections This setting limits the number of client connections to the server.
The default value is 256 but could be increased if there is heavy
network trafc.
ARP Cache Size This setting limits the number of cache entries available in the ARP
table. The default setting of 256 is adequate for most instances
TCP Reassembly Queue Limit This setting limits the maximum number of TCP segments allowed in
the reassembly queue, to protect against a common DoS attack.
Remote Codec Default Connection
This selects the initial connection type to use for an auto congured
remote codec camera, select from TCP or UDP
System (Red) Select to open the System->Features->System page
Network (Green) Select to open the System->Features->Network page