User guide

Dedicated Micros ©2011
10
CamVu D500 Minidome
Recess Mount Installation
Refer to the Quickstart section for more information.
1 To recess mount the camera, the shroud must be removed. Gently squeeze together opposite
sides of the shroud as shown and lift it away from the camera body.
2 Using the template supplied at the rear of this manual, mark and cut a 4” (100 mm) diameter
hole. A suitably sized hole saw can also be used.
To prepare for installation use a suitable screwdriver to loosen the three xing clamps
sufciently to accommodate the thickness of the tile or ceiling.
3 Connect the ethernet cable to the RJ45 socket on the mainboard. If the camera is connected
to a switch that is not POE capable, refer to ‘POE Injector Cable ‘ and install the POE injector
cable as described.
4 Insert the camera into the hole. Using a suitable screwdriver, tighten the three xing clamps as
shown. Do not overtighten the clamps.
Camera Adjustment
Camera Position
The camera assembly is adjustable in all three axes. Adjust the camera until it is pointing in the desired
direction.
FOV & Focus
Use the levers on the varifocal lens to adjust the camera’s eld of view, and focus.
Local Video Out
Provision is made for the connection of a local video monitor to assist in setting up the camera. Use the
optional service connector DM/ICED-SERV (not supplied).