Zone OR Input  The Zone OR Input identies an alternative input that can also be 
used to trigger the zone alarm. This means an alarm trigger can 
be received on the Zone Alarm Input or the Zone OR Input for the 
trigger to be activated.
Zone AND Input 
The Zone AND Input identies that an alarm trigger needs to be 
received on both the Zone Alarm Input and the Zone AND Input 
for the trigger to be activated and the alarm action to the   
automatically initiated. 
Zone NOT Input 
The unit will only issue the alarm actions if the trigger is received 
on the zone alarm input and NOT on the Zone input. 
Alarm 24Hr  This option can be enabled for alarms that do not require change 
at any time and are to remain as programmed i.e. Panic Alarm. 
When this is selected, the Set, Unset and Override options are 
disabled.
Entry Route Zone  This creates deferred alarms along a specied route while the 
entry time is active. This is in compliance with BS8418 (the British 
Standard for remote video reporting centres). Diverting from the 
entry route during the countdown will result in the alarm being 
triggered immediately. This allows staff entry without triggering an 
alarm prior to switching the system to Set mode.
Exit route Zone  This creates deferred alarms along a specied route while the 
exit time is active. This is in compliance with BS8418 (the British 
Standard for remote video reporting centres). Diverting from the 
exit route during the countdown will result in the alarm being 
triggered immediately. This allows staff to exit without triggering 
an alarm.
Exit Terminator  This will trigger the exit timer if the system is set. A countdown 
timer will automatically start when the alarm is activated and 
ensure the alarm system is not activated by other specied alarm 
triggers for the Set time i.e. allowing a Guard to exit a building.
Entry Initiator  This will trigger the entry timer if the system is set. A countdown 
timer will automatically start when the ‘primary’ alarm trigger 
i.e. front door, is actioned. This ensures the alarm system is not 
activated by other specied alarm triggers for the set time
Enable in Unset  Each alarm can be congured to be active when the unit is in 
a specic operation mode. Enable this for the zone alarm to be 
active in Unset operation mode.
Enable in Set  Each alarm can be congured to be active when the unit is in 
a specic operation mode. Enable this for the zone alarm to be 
active in Set operation mode.
Enable in Override  Each alarm can be congured to be active when the unit is in 
a specic operation mode. Enable this for the zone alarm to be 
active in Override operation mode. 