Installation Instructions

Joist Span
Joist Span
Up to
6 ft.
Up to
8 ft.
Up to
10 ft.
Up to
12 ft.
Up to
14 ft.
Up to
16 ft.
Up to
18 ft.
Connection Details
Loading
Condition
Maximum on center spacing of fasteners (inches)
Maximum on center spacing of fasteners (inches)
Maximum on center spacing of fasteners (inches)
Maximum on center spacing of fasteners (inches)
Maximum on center spacing of fasteners (inches)
Maximum on center spacing of fasteners (inches)
Maximum on center spacing of fasteners (inches)
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
1/2 inch lag screw
3
4
5
6
40 / 10
36*
36*
36*
32
27
24
21
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
1/2 inch lag screw
3
4
5
6
60 / 10
36*
34
27
22
19
17
15
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
1/2 inch bolt
5
6
40 / 10
36*
36*
36*
36*
35
30
27
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
1/2 inch bolt
5
6
60 / 10
36*
36*
35
29
25
21
19
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
5/8 inch lag screw
3
4
5
6
40 / 10
36*
36*
36*
35
30
26
23
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
5/8 inch lag screw
3
4
5
6
60 / 10
36*
36*
30
25
21
19
17
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
5/8 inch bolt
5
6
40 / 10
36*
36*
36*
36*
36
32
28
5/8 inch Deck2wall Spacers
1
19/32 inch maximum sheathing
2
5/8 inch bolt
5
6
60 / 10
36*
36*
36
30
26
23
20
The fastening table below is based on test data from an ICC-IAS
accredited test lab. Testing was performed using established methods
which are the basis for the deck ledger connection provisions in
R502.2.2.1 of the 2009 IRC and R507.2 of the 2012 IRC.
1. Deck2wall Spacers Model D2W58 shall be installed to ledger with 3 - #8 x 1 5/8” Phillips Square-Driv® or
GuardDog® screws or equal. Use only premium exterior coated or 300 series stainless steel, 1 5/8” minimum
length, #8 or larger. Screws must provide suitable corrosion resistance for the preservative treated lumber and
environmental conditions.
2. Maximum 5/8” nominal wood structural sheathing shall be fastened per code.
3. The tip of the lag screw shall fully extend beyond the inside face of the band joist.
4. Lag screw connections require a washer under the lag screw head.
5. Lag screws and bolts shall be hot dipped galvanized or stainless steel.
6. Lag screws and bolts shall be placed 4 diameters in from the top or bottom of the deck ledgers, and between 2 1/2
and 5 inches from the ends. End fasteners shall be located near the bottom of the ledger. The lag screws or bolts
shall be staggered along the horizontal run of the deck ledger, similar to IRC R507.2.1. See figure below.
* These spacings were limited for consideration of the bending strength of a 2 x 8 minimum ledger between fasteners.
Deck2wall, Inc. - Rohnert Park, California
For more information call Toll Free 888 577-2237 or visit www.deck2wallspacer.com
Deck2wall Spacer™ US Patents 6,945,004 and 8,087,207
Deck Ledger Fastening Table for Deck2wall Spacer™ Model #D2W58
Deck ledger shall be minimum 2 x 8 nominal sawn lumber, pressure preservative treated Hem-Fir, Douglas Fir or
Southern Pine. Band joist shall be nominal 2x solid sawn SPF, Hem-Fir, Douglas Fir or Southern Pine.
60 PSF Live Load and 10 PSF Dead Load
Tested at ICC-IAS accredited Composite Materials and Engineering Center (CMEC) at Washington State University.
Phillips Square-Driv® and GuardDog® are registered trademarks of their respective companies.
Structural Sheathing
19/32" Max.
2x Band Joist
Deck Ledger
2x8 Minimum
Stagger Fasteners
Vertically
5/8" Deck2wall
2 1/2 - 5" From End of Ledger
On Center Spacing of Fasteners
See Table
4x Fastener Diameter Minimum
From Ledger Top & Bottom
Spacers each to be
attached with three
#8 x 1 5/8" exterior
wood screws
Exterior cladding & water
proofing not shown for clarity
Effective January 1, 2016.
Check our website or contact Decks