Technical Specs
2. Standards of CONSOLE 3
2.1. 2011/65/UE Directive “RoHs 2”
2.2. REACH directive
2.3. R&TTE directive
2.4. Temperature cycling test.
Low temperature : (‐ 10 ± 2)°C during 10 min
High temperature : (+60 ± 2)°C during 10 min
Cycles : 50 Times
2.5. Temperature storage test.
+60°C during 24 hours consecutive
2.6. ESD test.
Air: ±12KV
Contact: ±7KV
Reports are inside PACE
3. USER-keyflow and Machine-Keyflow
User-keyflow is the main keyflow used by end-customer.
CONSOLE 3 -
Keyflow.pdf
DECATHLON CONTROL
Test can be done using a bike or jig simulator proposed by CY.
Functional test of the user-interface of the console :
1) Displays are working and information values are changing during a training cession.
(Kcal, distance, time, rpm, BPM (
when active
), resistance level)
2) Heart-logo is changing color from blue – green – yellow – orange – red – according to
heart-rate value.
3) Each touch-key is activate during a finger touch contact < 1second
4) Servo-motor is turning when increase or decrease a resistance level (0 to 15)
ACCEPTANCE CRITERIA
Main functions are ok
Machine-keyflow is a ghost menu for maintenance. This menu can check :
1. The firmware version of the console