Specifications

7-3
7.3 Main Burner Malfunctions (cont.)
D. Fryer will not reach the temperature setting and/or runs erratically.
1. Incorrect location of sensor probe or defective temperature sensor.
2. Loose wiring/wire connection
E. Fryer shortening temperature cannot be controlled; fryer runs at high-limit temperature.
1. Defective operating thermostat or temperature probe.
2. Call Service Technician.
7.4 Thermatron Calibration
The Thermatron controller maintains a specific oil/shortening temperature through a sensing probe
mounted in the fry vessel. If the actual temperature of the cooking oil varies from the controller dial
setting, loosen the knob setscrew and rotate the knob until it agrees with that of the actual oil
temperature. When obtaining actual oil temperature, ensure that the thermometer is inserted within
one-inch of the vessel-mounted probe. If proper calibration cannot be achieved, contact your service
agent for repair.
Control Knob Setscrew (counter-set in knob)
Thermatron Probe