5.3 Operating Fryers with Thermatron Controllers (cont.)
INDIVIDUAL FRYER POWER SWITCHthis switch controls power to the individual fryer,
whether the fryer is in the Thermatron mode or the back-up mode. When the power switch is in the
"ON" position, the indicator light will be lighted when calling for heat. The power switch only
removes power from the temperature control circuit (Thermatron and Back-Up Thermostat). The
power switch should be in the "OFF" position during filtering.
BOIL-OUT SWITCH this only operates when in the Thermatron mode. When the Boil-Out
switch is "ON", it will bypass the Thermatron Melt Cycle, and allow the water temperature to reach
approximately 196°F.
FILTER POWER SWITCH (Optional) – controls power to the filter pump. Individual Power
Switch should be in "OFF" position when in use.
HIGH-LIMIT RESETthis reset button is located under each individual control panel, and must
be manually reset if the fryer exceeds high-limit setpoint.
FILTER RESET SWITCH (7 Amp Circuit Breaker) the breaker is in line between the filter
switch and the pump. Turn filter power switch "OFF" prior to replacing.
5 AMP FUSE – each two fryer circuits are protected by a 5 amp fuse located under the 2
nd
and 4
th
control panel.