Specifications
3-6
3.5 Gas Connections (cont.)
J. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.
K. CE Standards: If the unit is to be installed with flexible coupling, use a commercial flexible
coupling certified as NF D 36123 (or other national standard) or a quick disconnect device
certified NF D 36124 (or other national standard).
3.6 Adjustments/Adaptation To Different Gases
A. Proper operation of appliances requires operator to scrupulously inspect the following
adjustments in terms of:
1. Gas inputs and pressures.
2. Voltage and polarities of electrical power supplies.
B. Dean gas fryers are manufactured to use the type of gas and pressure specified on the rating
plate. When changing to a different gas, adaptation must be performed by qualified
personnel. Failure to use qualified personnel will void the Frymaster warranty.
3.6.1
CE Specifications
3.6.1.1 Gas Types and Specifications
EQUIPMENT
PRESSURE
MODEL
INPUT
(kW)
GAS
TYPE
ORIFICE
MM (INCH)
ORIFICE
PART NO.
QTY/
COLOR
MBAR INCH WC
PRESSURE
MBAR
PILOT
ASSEMBLY
D20G 15
G20
G25
G31
2.40(#42)
2.40(#42)
1.51(#53)
14-0067-10Blu
14-0067-10Blu
14-0067-2Red
2/BLUE
2/BLUE
2/RED
10
15
27
4.0
6.0
10.8
20MBAR
25MBAR
37MBAR
14199-1CE
14199-1CE
14199-2CE
D50G 30
G20
G25
G31
2.40(#42)
2.40(#42)
1.51(#53)
14-0067-10Blu
14-0067-10Blu
14-0067-2Red
4/BLUE
4/BLUE
4/RED
10
15
27
4.0
6.0
10.8
20MBAR
25MBAR
37MBAR
14199-1CE
14199-1CE
14199-2CE
D60G 37.5
G20
G25
G31
2.40(#42)
2.40(#42)
1.51(#53)
14-0067-10Blu
14-0067-10Blu
14-0067-2Red
5/BLUE
5/BLUE
5/RED
10
15
27
4.0
6.0
10.8
20MBAR
25MBAR
37MBAR
14199-1CE
14199-1CE
14199-2CE
D80G 37.5
G20
G25
G31
2.40(#42)
2.40(#42)
1.51(#53)
14-0067-10Blu
14-0067-10Blu
14-0067-2Red
5/BLUE
5/BLUE
5/RED
10
15
27
4.0
6.0
10.8
20MBAR
25MBAR
37MBAR
14199-1CE
14199-1CE
14199-2CE