Programming instructions

DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-28
1.7.8 Replacing the Frypot (cont.)
27. Remove the temperature probe from frypot. (see Section 1.7.3, Replacing Temperature Probe for
specific instructions.
28. Remove the high-limit (see Steps 5-7, Section 1.7.4- Replacing the High-Limit Thermostat) and
backup thermostat [see Section 1.7.2- Replacing Backup Thermostat (where applicable)] from
frypot.
29. If the fryer is equipped with
drain-valve microswitches, mark
the wires and microswitch
terminals, then disconnect wires
from the switch. Secure the wires
to prevent damage when frypot is
removed.
30. Remove bolts from brackets
securing burner manifold to
frypot. Leave the manifold in
place.
Left: Microswitch wires marked for removal (ensure
microswitch terminals are marked the same as the wires
removed). Right: Microswitch mounted to drain valve.
Removing bolts (arrows) from burner manifold support
brackets (both sides). Leave the burner manifold in place
after removing bolts.