Programming instructions

DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-17
1.7.4 Replacing the High-Limit Thermostat (cont.)
8. Mark and disconnect wires at the high-limit
in the component box.
9. Remove high-limit from fryer by pulling the
capillary tube and bulb through the
component box opening (arrow). (This may
require removal of the control panel frame.)
10. Reverse the above steps for high-limit
installation.
IMPORTANT: When installing new high-limit
or backup thermostat, ensure the capillary tube
and bulb are positioned properly with the
mounting hardware installed prior
to tightening
the compression nut. Once tightened, the
capillary tube cannot be repositioned.
Mark and disconnect high-limit wiring (arrows).
(Reconnect wires to the same terminals on the
replacement high-limit.)
Pull the capillary tube and bulb up and through the
component box opening to remove old high-limit.
Removing the control panel frame will facilitate
high-limit removal. Replace control panel frame
after new high-limit has been installed.