Programming instructions

DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-14
1.7.3 Replacing the Temperature Probe (Computer-Equipped Fryers-cont.)
6. Loosen and unscrew completely the
compression nut, then the pass-through nut
from the frypot. Proceed to the next step
before removing probe from frypot.
Note: The temperature probe can be
removed through the top of the frypot as
follows: Ensure the two-pin connector has
been removed from the probe wiring harness
(step 4, this section). Remove the harness
insulation. The probe can be pulled through
the frypot from the top (complete step 7, this
section, prior to removing probe).
7. Remove probe bracket and probe spring from
probe inside frypot (bracket location and
configuration will vary according to fryer
model). Retain mounting hardware for
installation of new temperature probe.
8. Carefully remove the probe from the frypot.
As the probe is removed, tilt the probe at an
angle to facilitate removal (curved probes
only).
9. Reverse steps for installation of new probe.
IMPORTANT: When installing new probe,
ensure probe is positioned properly with the
mounting hardware installed prior
to tightening
the compression nut. Once tightened, the probe
cannot be repositioned.
Loosen and unscrew completely the compression
nut (bottom arrow), then the pass-through nut (top
arrow
.
First remove the probe bracket (two screws), then
the probe spring. Retain mounting hardware fo
r
installation of new
p
robe.
First remove the probe bracket (two screws), then
the probe spring. Retain mounting hardware fo
r
installation o
f
new
p
robe.
Removing old probe from frypot. (Frypot removed
from fryer for clarity).