Programming instructions

DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-13
1.7.3 Replacing the Temperature Probe (Computer-Equipped Fryers)
1. Disconnect the fryer from the electrical supply.
2. Drain cooking oil/shortening from the frypot. Allow the frypot to cool completely before
proceeding.
3. Remove the fryer door for easier access to the
temperature probe. Lift door up, disengage
rod from lower door bracket, and then
remove door.
4. Disconnect the probe harness connector
(arrow). Use a pin pusher to remove plug
from probe wires (probe side only). Retain
the plug for re-assembly on new probe.
5. Remove the appropriate burners to gain
access to the temperature probe (see Steps
20-22 for more detail).
Remove door for easier access to temperature
probe.
Disconnect the two-pin probe harness connector
(arrow).
Remove burners to gain access to temperature
probe.