1.7.9 Replacing the Frypot (cont.)
29. Position the frypot upside down on a
suitable work surface.
30. Record position of the valve stem in
relation to the frypot prior to removing
the drain valve. If equipped, remove
microswitches and mounting hardware
from valve prior to removal. Using a
suitable wrench, remove the drain valve
from the frypot. Use Loctite PST567
sealant when installing drain valve on
replacement frypot.
31. Remove all other hardware and
accessories from the frypot.
32. Reverse the above steps to install the
replacement frypot.
33. Add a bead of silicon around the edges of
the new frypot, sealing the seam where
the frypot and the cabinet meet. Only do
this when the frypot is completely
installed.