User Manual
64 IM-pAC Getting Started Guide
www.camcoindex.com | www.destaco.com Issue Number: 5
Figure 7-12 Brake function diagram
Figure 7-13 Brake sequence
Pr 52 to Pr 54 appear when a Solutions Module is installed in the drive.
See the appropriate fieldbus Solutions Module manual for further information.
Current
magnitude
Brake release
current threshold
Brake apply
current threshold
46
47
+
_
Motor
frequency
Brake release
frequency
Brake apply
frequency
48
49
+
_
+
_
Reference
enabled
Latch
Drive
active
In
Out
Reset
Pre-brake
release
delay
50
Post brake
release
delay
51
Brake
release
Brake
controller
enable
12
T5
T6
B3
User
programmable
Brake
disabled
Ramp
hold
Pr Brake
release frequency
48:
Pr : Brake release
current threshold
46
Ramp hold
Pr :
Brake apply
frequency
49
Pr :
Pre brake
release delay
50
Pr :
Post brake
release delay
51
Brake release
Output current
Output frequency
No Function Range Defaults Type
52
*Solutions Module dependant 0 to 255 0 RW
No Function Range Defaults Type
53
*Solutions Module dependant 0RW
No Function Range Defaults Type
54
*Solutions Module dependant 0RW