Safety Information Rating Data
Mechanical
Installation
Electrical Installation Keypad and Display
Parameters
Diagnostics
UL Listing
Information
Figure 7-4 Pr 05 = Pr
Figure 7-5 Pr 05 = PAd
Setting-up a Forward/Reverse terminal in Keypad mode
From the drive’s display:
•Set Pr 71 to 8.23
•Set Pr 61 to 6.33
• Press the Stop/Reset key
Terminal B5 will now be set-up as a Forward/Reverse terminal
0V
+10V reference output
+24V output
Drive Enable/Reset
Run Forward
Run Reverse
V
_
+
+24V
0V
Eur USA
Analog output
(motor speed)
Digital output
(zero speed)
Reference select
Reference select
0V
+10V reference output
+24V output
/Stop
Run
Jog
V
_
+
+24V
0V
Analog output
(motor speed)
Digital output
(zero speed)
Not used Not used
Reference select
Reference select
T1
T2
T3
T4
B1
B2
B3
B4
B5
B6
B7
T1
T2
T3
T4
B1
B2
B3
B4
B5
B6
B7
T4 B7 Reference selected
0 0 Preset 1
0 1 Preset 2
1 0 Preset 3
1 1 Preset 4
0V
+10V reference output
+24V output
Drive Enable/Reset
V
_
+
+24V
0V
Eur USA
Analog output
(motor speed)
Digital output
(zero speed)
Not used
Not used
Not used
Not used
0V
+10V reference output
+24V output
Drive Enable/Reset
V
_
+
+24V
0V
Analog output
(motor speed)
Digital output
(zero speed)
Not used
Not used
Not used
Not used
T1
T2
T3
T4
B1
B2
B3
B4
B5
B6
B7
T1
T2
T3
T4
B1
B2
B3
B4
B5
B6
B7
Forward/Reverse Forward/Reverse