User Manual
IM-pAC Getting Started Guide 35
Issue Number: 5 www.camcoindex.com | www.destaco.com
Read Me First
Instructions
Safety Information
Rating Data
Mechanical
Installation
Electrical Installation Keypad and Display Parameters Diagnostics
UL Listing
Information
3Rating Data
Table 3-1 120V drive
Table 3-2 200V drive
Table 3-3 400V drive
Model Number
Nominal
Motor Power
Supply voltage
and frequency
Typical
full load
input
current
A
100% RMS
output
current
A
150%
overload
current for
60s
A
Minimum
braking
resistor
value
Ω
hp kW 1ph Heavy Duty
92B90482070000 1.0 0.75
1 phase
10
0 t
o 120V ±10%
48 to 62 hz
19.6 4 6 28
92B90482080000 1.5 1.1
1 phase
100
to 1
20V±10%
48 to 62 hz
24 6 7.8 28
Model Number
Nominal
Motor Power
Supply voltage
and frequency
Typical
full load
input
current
A
100% RMS
output
current
A
150%
overload
current for
60s
A
Minimum
braking
resistor
value
Ω
hp kW 1ph Heavy Duty
92C85797010000 1.0 0.75
1 phase
200 to 240V ±10%
48 to 62 hz
10.5 4.0 6.0 68
92B9048
2010000 1.5 1.1
1 and 3 phase
200 to 240V ±10%
48 to 62 hz
14.2 16.7 5.2 7.8 28
92B90482020000 2.0 1.5
1 and 3 phase
200 to 240V ±10%
48 to 62 hz
17.4 8.7 7.0 10.5 28
92B9048
2030000 3.0 2.2
1 and 3 phase
200 to 240V ±10%
48 to 62 hz
23.2 11.9 9.6 14.4 28
Model Number
Nominal
Motor
Power
Supply voltage
and frequency
Typical
full load
input
current
A
Maximum
continuous
c u r r e n t
A
100%
RMS
output
current
A
150%
overload
current
for 60s
A
Minimum
braking
resistor
v a l u e
Ω
hp kW 3ph Heavy Duty
92C85797020000 1.0 0.75
3 phase
380 to 480V ±10%
48 to 62 hz
3.1 3.75 2.1 3.2 100
92B9048209000 1.5 1.
1
3 phase
380 to 480V
±10%
48 to 62 hz
4 4.6 2.8 4.2 100
92B90482040000 2.0 1.5
3 phase
380
to 480V
±10%
48 to 62 hz
5.2 5.9 3.8 5.7 100
92B90482050000 2.2 3
3 phase
380 t
o 480V ±10%
48 to 62 hz
7.3 9.6 5.1 7.65 100
92B9048
2060000 4 5
3 phase
380 to 480V ±10%
48 to 62 hz
11.9 13.4 9.0 13.5 55