User Manual

www.destaco.com 9
3. Under “Ports, the VCP should be shown as COM6. If it is not 6,
note the number shown.
Note: If the Com port is not 6, then you must change the text in
the file eswitchcomport.txt from 6 to the Com port number as
noted in step 3. This file is located in the same directory as the
program eSwitch.
4. Configure the communications port with the following settings:
Baud Rate 9600 bps
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
Program the eSwitch
CAUTION: When programming of the eSwitch is complete, remove
the USB cable from the eSwitch and put the blue cover back on the
USB port on the eSwitch. Failure to replace the cover could result in
damage to the eSwitch.
1. Connect the switch to the computer with a USB cable and
provide power to the eSwitch
2. Run eSwitch.exe